Air Solenoid Valve Controller Unit

▷ It controls the two SOL(Solenoid-Valve) with a simple operation

▷ Support external input switch(start/reset key)

▷ 12~24V adapter available(Used for the VDC on the SOL-PRODUCT) 

▷ 4 modes of operation supported

    (Add contact during operation other than the default)   

▷ Specifications

- INPUT VOLTAGE : DC 12V, 24V (Used for the VDC on the SOL-PRODUCT)

- OUTPUT : 2PORT / SINGLE (1 Ext Additional ports in question)

- INPUT : START, SET, UP, DOWN, EXT KEY Support(START/RESET)

◇ START :  START / STOP BUTTON

◇ UP : TIMER / COUNT increase

◇ DOWN : TIMER / COUNT decrease

◇ SET : Parameter Settings

◇ MODE : DIP SW Setting(See Table Setting)

- SIZE : 105*80*20mm

▷ Detail of fuction

- Mode 1 : XX -> OO-> XX
- Mode 2 : XX -> OX -> XX -> XO -> XX
- Mode 3 : XX -> OX -> OO -> XO -> XX
- Mode 4 : XX -> OX -> OO -> OX -> XX

◆example)

1. 'XO' Description of the operation

  -> The first symbol 'X' is the SOL1 OFF / Second symbol 'O' is the SOL2 ON

2. 'OX' Description of the operation

  -> The first symbol 'O' is the SOL1 ON / Second symbol 'X' is the SOL2 OFF

3. 'OO' Description of the operation

  -> The first symbol 'O' is the SOL1 ON / Second symbol 'O' is the SOL2 ON

4. 'XX' Description of the operation

  -> The first symbol 'X' is the SOL1 OFF / Second symbol 'X' is the SOL2 OFF

5. Operation example) Operation and the setting of the MODE3

   d1     d2     d3      d4

    XX -> OX -> OO -> XO -> XX
|<----   All Repeat (d0)   ---->

- Upon entering the SET key to go to each parameter

    Each parameter setting procedure : 'r'->'d0'-> 'd1'->'d2'->'d3'->'d4'

- d0~d5 is the waiting time and can be set to 1~9sec

- 0 seconds setting is set to manual operation and also during the following operations Enter the Start key

- r is the total number of repeats set

■ MODE DIP SW Table Setting