Air Solenoid Valve Controller Unit
▷ It controls the two SOL(Solenoid-Valve) with a simple operation
▷ Support external input switch(start/reset key)
▷ 12~24V adapter available(Used for the VDC on the SOL-PRODUCT)
▷ 4 modes of operation supported
(Add contact during operation other than the default)
▷ Specifications
- INPUT VOLTAGE : DC 12V, 24V (Used for the VDC on the SOL-PRODUCT)
- OUTPUT : 2PORT / SINGLE (1 Ext Additional ports in question)
- INPUT : START, SET, UP, DOWN, EXT KEY Support(START/RESET)
◇ START : START / STOP BUTTON
◇ UP : TIMER / COUNT increase
◇ DOWN : TIMER / COUNT decrease
◇ SET : Parameter Settings
◇ MODE : DIP SW Setting(See Table Setting)
- SIZE : 105*80*20mm
▷ Detail of fuction
- Mode 1 : XX -> OO-> XX
- Mode 2 : XX -> OX -> XX -> XO -> XX
- Mode 3 : XX -> OX -> OO -> XO -> XX
- Mode 4 : XX -> OX -> OO -> OX -> XX
◆example)
1. 'XO' Description of the operation
-> The first symbol 'X' is the SOL1 OFF / Second symbol 'O' is the SOL2 ON
2. 'OX' Description of the operation
-> The first symbol 'O' is the SOL1 ON / Second symbol 'X' is the SOL2 OFF
3. 'OO' Description of the operation
-> The first symbol 'O' is the SOL1 ON / Second symbol 'O' is the SOL2 ON
4. 'XX' Description of the operation
-> The first symbol 'X' is the SOL1 OFF / Second symbol 'X' is the SOL2 OFF
5. Operation example) Operation and the setting of the MODE3
d1 d2 d3 d4
XX -> OX -> OO -> XO -> XX
|<---- All Repeat (d0) ---->
- Upon entering the SET key to go to each parameter
Each parameter setting procedure : 'r'->'d0'-> 'd1'->'d2'->'d3'->'d4'
- d0~d5 is the waiting time and can be set to 1~9sec
- 0 seconds setting is set to manual operation and also during the following operations Enter the Start key
- r is the total number of repeats set
■ MODE DIP SW Table Setting